HUT™ Tilt Table
The Head Up Tilt™ Table (HUT™ Table) is designed to assist with head-up tilt testing, with the capability to move from 70° head-up reverse Trendelenburg to level in approximately 11 seconds. The reverse Trendelenburg (tilt) positioning can be adjusted to accommodate various needs and testing protocols.
Patients are secured with Patient Safety Straps and supported on the Integrated Folding Foot Platform, helping to provide a stable environment for syncope evaluation. The design of the tilt table is intended to offer comfort for both patients and clinicians during head-up tilt table tests.
The HUT™ Table is available with optional drop sections, which may allow for improved access during certain imaging procedures, potentially offering added flexibility for different clinical applications.
Optional features of our HUT™ Table may be pictured
Our HUT™ Table is designed for:
• Cardiologists
• Electrophysiologists
• Research Physicians
HUT™ Tilt Table Specification Sheet
Height Positioning | 31″ to 39″ |
Trendelenburg/Reverse Trendelenburg Positioning | 15°/90° |
Maximum Patient Capacity | 400 lbs. |
Patient Surface Width | 30″ |
Patient Surface Length | 73″ |
Warranty | 1 Year |
Foam | California Technical Bulletin 117 – Section E |
Electrical | 100-240VAC, 50/60Hz 5A |
Vinyl | California T.B. 117-2013, NFPA 260- Cover, Fabric – Class I, UFAC Fabric – Class I |
Compare Echocardiography Tables Features
EchoBed® X | Stress EchoBed® | VasScan Table™ X | EchoTable™ | HUT™ Tilt Table | RR HUT™ Tilt Table | UltraScan® Versa™ Table | UltraScan® Versa™ Premier Table | |
Height Positioning | 19″ to 38″ | 24″ to 34″ | 19″ to 38″ | 24″ to 34″ | 31″ to 39″ | 31″ to 39″ | 22″ to 38″ | 22″ to 38″ |
Fowler Positioning | Optional – 0° – 65° | N/A | 0° – 65° | Optional – 0° – 65° | N/A | N/A | 0° – 90° | 0 ° – 90° |
Trendelenburg/Reverse Trendelenburg Positioning | Optional – 15°/15° | 15°/15° | 15°/30° | Optional – 15°/15° | 15°/90° | 15°/90° | Optional – 15°/15° or 15°/25° | 15/25° |
Lateral Tilt Positioning | N/A | 40° | N/A | N/A | N/A | N/A | N/A | N/A |
Maximum Patient Capacity | 600 lbs. | 500 lbs. | 600 lbs. | 500 lbs. | 400 lbs. | 600 lbs. | 500 lbs. | 500 lbs. |
Width | 30″ | 30″ | 28″ | 28″ | 30″ | 30″ | 28.5″ | 28.5″ |
Length | 80.5″ | 78″ | 80.5″ | 79.5″ | 73″ | 73″ | 72.5″ | 72.5″ |
Warranty | 5 Years | 5 Years | 2 Years | 3 Years | 1 Year | 3 Years | 2 Years | 5 Years |
Foam | California Technical Bulletin 117 – Section E | California Technical Bulletin 117 – Section E | California Technical Bulletin 117 – Section E | California Technical Bulletin 117 – Section E | California Technical Bulletin 117 – Section E | California Technical Bulletin 117 – Section E | TB 117-2013 Section E | TB 117-2013 Section E |
Electrical | 100-240VAC 50/60Hz 5A | 120 VAC, 50/60 Hz, 2.6A Max | 100-240VAC, 50/60Hz 5A | 100-240VAC, 50/60Hz 5A | 120 VAC, 60Hz, 6.5A, 230 VAC, 50 Hz, 3.4A | 120 VAC, 60Hz, 6.5A, 230 VAC, 50 Hz, 3.4A | 100 – 240 VAC, 50/60 Hz, 4.5A Max | 100 – 240 VAC,50/60 Hz,4.5A Max |
Vinyl | California T.B. 117-2013 NFPA 260- Cover, Fabric – Class I, UFAC Fabric – Class I | California T.B. 117-2013, NFPA 260- Cover, Fabric – Class I, UFAC Fabric – Class I | California T.B., 117-2013, NFPA 260- Cover, Fabric – Class I UFAC, Fabric – Class I | California T.B. 117-2013, NFPA 260 – Cover, Fabric – Class 1, UFAC Fabric – Class 1 | California T.B. 117-2013, NFPA 260- Cover, Fabric – Class I, UFAC Fabric – Class I | California T.B. 117-2013, NFPA 260- Cover, Fabric – Class I, UFAC Fabric – Class I | TB 117-2013, NFPA 260 Cover Fabric – Class 1, UFAC Fabric – Class 1 | TB 117-2013, NFPA 260 Cover Fabric – Class 1, UFAC Fabric – Class 1 |